I am seeking a position as an Project manager Engineer, specializing in applications within a progressive and forward-thinking company. I am eager to utilize my skills in a career that offers growth potential. I am an outgoing, high-energy individual with strong communication abilities.
-Skilled lead electrical engineer with experience in the power plant. familiar with GE & SIEMENS electrical equipment’s generators and its accessories Excitation & Static Starter and its software. -MV switchgear (SIEMENS-ABB-SCHNIDER), power transformers, GIS switch yard one and half circuit breaker (SIEMENS-HHI, -Protection relays (G60, C60, T60, SEPAM (S40, S42, B, 21, M87), SEIMENS RELAY SIPROTEC 4 (7UT612,7SJ,7SA522 and etc., SIPROTEC 5(7SJ82-85 - 7UT85 -7SK85) ABB relays (REF620-REF615-REM615)
Overview
18
18
years of professional experience
Work History
Electrical Expert
SAUDI ELECTRICITY COMPANY (SEC)
Riyadh, KSA
04.2023 - Current
Responsible of Testing and Commissioning activities of current and upcoming new projects as well as inspection of EPP equipment.
Coordinate and witness of GRID CODE Performance tests (O/C & load control, UEL, OEL, PSS, Direct axis, governor droop, Excitation response, house load and V/F etc.) for (EEP 13th, EPP 14th, Duba Green).
Collaborate and coordinate with the Project Development Company (PDC) during the project's commissioning phase to review and approve t (T&C) procedures. Now (EEP 13th, EPP 14th, Duba Green).
Oversee and evaluate the testing and commissioning processes, ensuring strict adherence to international standards and regulatory requirements.
Continuously monitor key performance indicators (KPIs) related to testing and commissioning efficiency, accuracy, and effectiveness.
Collaborate with engineering and maintenance teams to optimize testing and commissioning processes for enhanced performance.
Participate to factory acceptance tests of critical packages and equipment.
Review timetables for testing & commissioning and follow-up with the equipment provider to ensure the completion of tests according to the required schedule.
Reviews the commissioning & testing results regarding all equipment tests and confirm that purchased equipment’s & devices is covers the requirements contracted by the company and the resulting values is meet the station's needs for the long term.
Ensure that inspection processes align with the latest international quality benchmarks.
Approve testing of EPPs equipment to ensure compliance with safety and performance standards.
Witness SAT of all EPPs equipment and ensure all T&C activities done as per Company requirements.
Collaborate closely with engineering teams to streamline the prequalification process, ensuring that contractors can be approved by the SEC and seamlessly integrated into the ACL system.
Participate in the tendering process by providing the required scope of work (SOW) documents and pricing attachments.
Searching and applying new technology inspection for main EPPs assets.
Senior Electrical Commissioning Engineer
SHANHAN ENGINEERING
Riyadh, KSA
03.2022 - 03.2023
Protection Relay Scheme check for Generator Protection panel, GSUT commissioning, UAT Commissioning, GSUT-, UAT-, Testing and Commissioning of GCB, 480V switchgear, 6.9 kV switchgear, 13.8 kV switchgear, interlock and Inter trip check & Trip Test between Substation and Power plant, Stability for UAT, GSUT, Generator and Overall Units, EDG Commissioning, Unit Back Charge and Unit start-up.
Https://shanahanengineering.com/
Lead Electrical Engineer
SAUDI ELECTRICITY COMPANY (SEC)
06.2016 - 06.2021
Responsible for supervising construction and commissioning of all Electrical works, assurance that all works have been done according to contract, Generation Engineering & Material Standard Specifications (GEMSS) and issue of punch list items.
Maintenance engineer responsible for maintenance and troubleshooting of all electrical equipment's during Normal Operation as well as during minor overhauls.
Preventive maintenance program for all types of electrical equipment's according to manufacture manuals.
Electrical works include: - Design Review: - Review and Modified the Generator Protection System (Main & Back-up), Generator Excitation System, Excitation Transformer, Synchronizing System, 250&400MVA GSUT, 63MVA UAT Overall Protection, BSDG Control and Protection, VFD Transformers, ALSTOM GCB Control Panel, 250&400MVA - HYUNDAI GSUT Control Panel (OFAF cooling system), UAT Transformers Control Panels, AVR, Tariff Metering, Fault Recorder, Interface and interlock drawings, HSTS, ATS, Oil type power distribution transformers, Dry type transformers, 13.8kV MV SWGR (Protection & Control Ckt's), 4.16kV MV SWGR (Protection & Control Ckt's), 480V LV SWGR, ACB Feeders "Air Circuit breaker" Protection & control schematic drawings, MCC's (Motor feeders) schematic drawing review, MCC's (Non-motor feeders), Dry type transformers, MV & LV Motors, IPB, SPB, NSPB, Battery chargers, UPS, Batteries, Lighting.
Review the installation method statement of: - Generator GSUT Transformers, UAT/ CAT Transformers, MV SWGRs, LV SWGRs, Control & Protection Panels, IPB, SPB and NSPB.
Field Inspection of Construction work: - Installation of 400&250MVA GSUT, 63/40/40MVA UAT ONAF Type Transformers, 13.8kV MV SWGR, 4.16kV MV SWGR, 480V LV SWGR ACB & MCC's, Dry type transformers, Oil type transformer " power distribution transformers", IPB, SPB, NSPB, Battery chargers and UPS, VFD panels, Indoor lighting system.
Testing & Commissioning Activities: - Schematic drawing check & update as per international standards, Contract Specifications and Site Requirements.
280MVA Generator Test (Hipot, Stator Winding Resistance, IR Test for Stator, Rotor Winding Resistance, IR Test for Rotor).
Testing of Overall Protection Panel (GE Main Relay G60, T60).
Unit Stability Test.
Testing of 250MW (GE) Generator Protection (G60 ).
Testing and Commissioning of Auto & Manual Synchronizing System.
Testing and Commissioning of Generator Excitation Transformer.
Excitation Transformer O/C Relay.
Testing and Commissioning of Static Excitation System EX2100e.
Generator PTs Cubicle and CTs.
Generator Neutral Transformer.
Testing of GSUT Protection Panels (Main & Back-up) (GE Main Relays T60).
Testing of UAT Transformers Protection (GE Main Relays T60) Main protection relay test for MV&LV SWGRs.
Coordinate and witness of GRID CODE tests (O/C & S/C saturation test, load rejection, UEL, OEL, Excitation response test, etc.)
400&250MVA OFAF Cooling Type 18/380kV GSU Transformer (HYUNDAI Manufacturer)-.
63/40/40 MVA Three winding ONAF Cooling UAT Transformers (ZTR Manufacturer).
GCB - (ALSTOM Manufacturer)
Oil immersed Transformers test.
Bus Bar stability test.
HSTS – SIEMENS Manufacturer (High speed transfer Switch).
125 & 220 VDC Battery Chargers function test (JEMA Manufacturer).
UPS & DC (JEMA Manufacturer) System function Test.
SWGR Arc protection relay test.
VCB &ACB Test (Siemens & ABB) Manufacturer.
Metering Ckt's Calibration..
MV / LV SWGR (CT & PT) Test.
LV SWGR & MCC auxiliary relay test.
Metering Ckt's (Tariff Metering, Digital Power meters, Analog ammeters & voltmeters).
CT test (Ratio, Saturation Curve Knee point, Resistance, Burden, polarity).
Bus Bar test (Stability, I/R, Contact resistance & Hipot test).
Battery (Charging & Discharging) Test.
Electrical commissioning Engineer
Middle Delta Electricity Production Company (MDEPC)
10.2012 - 06.2016
Responsible for supervising construction and commissioning all Electrical works, assurance that all works have been done according to contract and technical Specification and issue of punch list items.
Electrical works include:- Responsible for "Electrical drawings review and approval" According to the contract specification requirements.
Coordination and Supervision Of all Contractors Electrical Works and Identify any deviation from the contract for the following Contractors.
Generator, main transformer and Unit Auxiliary Transformers.
Generator Circuit Breakers.
GIS 220 KV switch yard Hyundai &Daewoo.
MV Switch Gear (Schneider Electric (MCset1,2,3) SF6/ 6.3 KV).
Batteries and Battery chargers and Uninterruptible Power Supply (UPS).
Medium & Low voltage cable, Interior and Exterior Illumination, Low current).
Electrical distribution Panels.
MV&LV Motors.
(6.3 Kv/400V) Transformers.
Lighting Systems of All Office Buildings.
Lighting Systems of the Yard.
Grounding system Generators: 324X017/018 (305 MVA HDROGEN COOLED) testing.
CT TEST (megger & turns ratio & dc resistance & polarity & saturation curve).
220 KV SF6 circuit breaker filling with Sf6 gas and testing (contact resistance & on/off time
Bus bar stability & sensitivity.
Breaker failure test & auto- reclosure test & pole discrepancy test.
High voltage test for GIs.
Check interlocking.
Power transformer (2x 300 MVA) (220/15.75 KV):- Function test for control cabinet.
Megger test.
Tan delta test.
Current transformer test.
Turns ratio.
Dc winding resistance.
Mechanical protection test and dielectric oil test…etc)
6.3 KV MV SWITCH GEAR (SCHNIDE SF6 C.B MC SET 1,2,3) 7.2 KV, 40KA S.C.
Perform function of operation test and alarms and signal indication are appearing correctly.
Perform functional interlock test (electrical & mechanical).
3-verfiy trip, close and anti-pumping function in test, local and remote position.
Sepam protective relay test (O.C (50/51) I ˃, I˃˃, E/F (50N/51N), over voltage (59), under voltage (27), etc. With secondary injection test.
Primary injection test.
Dc contact resistance.
Megger & hipot test.
Dc system :Batteries and Battery chargers and Uninterruptible Power Supply (UPS).
1-battery filling and charging and dis charging test.
2- Check battery charger mode of operation (floating, equalizing &boost).
3- Test all alarms for battery charger & ups and DCS signals.
4- Test inverter modes of operation (inverter, bypass &manual bypass).
Electrical Commissioning Engineer
Upper Egypt Electricity Production Company (UEEPC)
12.2009 - 10.2012
Responsible for maintenance and troubleshooting of all electrical equipment's during Normal Operation as well as during minor and major overhauls.
Preventive maintenance program for all types of electrical equipment's according to manufacture manuals.
Electrical works include: - GE & SIEMENS Generators maintenance and its excitation, LCI.
Power Transformers Maintenance (16.5/220kv&15.75/220KV, 180/240/300MVA).
Unit Auxiliary Transformer (16.5/6.3 KV,19.2/32 MVA).
Low voltage transformer dry type (6.3/0.4 KV).
MV switchgear maintenance (ABB breakers, Natus breakers, Schneider breakers).
MV & Low voltage motors (6.3 KV&0.4kv).
MCC (motor control center).
GIS 220 KV (One and half circuit breaker).
Battery, battery charger& UPS.
Electrical construction and commissioning Engineer
Upper Egypt Electricity Production Company (UEEPC)
06.2008 - 12.2009
UEEPC representative, Responsible for supervising construction and commissioning of all Electrical works, assurance that all works have been done according to contract and Specification and issue of punch list items.
Electrical works include: - Position: Electrical construction Engineer.
Duets: UPPEC representative, Responsible for following construction of all electrical works in the site and putting the remarks.
Electrical works include: Responsible for "Electrical drawings review and approval" According to the contract specification requirements.