VISION — EXECUTION — LEADERSHIP — RESULTS
To apply my 7 years of Telecom network architecture Design & implementation experience toward designing networks that will improve operational proficiency and reduce total costs of Maintenance of Datacenters & Implementation of Devices/projects.
Worked with different operators (STC, Zain, Mobily, ITC) on multiple Fixed\Core & WL\MW projects.
Responsibilities:
■ Supervise Installation of complete scope of IPNV, PTMS & VMS more then 8000 sites.
■ Supervise Mobile Dome Cameras Installation on Punjab Police vehicles and perform Rotkin test.
■ Supervise all kind of civil work, related to IPNV, PTMS and Signals poles as Excavation, Foundation and trench/bore work for power and Fiber cable laying including OP construction work.
■ Supervise Electrical Grounding work as per quality standards and costumer requirements.
■ Supervise the configuration and commission of Routers AR550, AR350, Signal Cabinet, and CPEs.
■ Worked on PTSC sites installation, Commissioning and troubleshooting. (Traffic intelligent system)
■ Supervise the installation of 2500KVA and 1250KVA also DG operation as second power source.
■ Installation Commissioning and troubleshooting of Power Cube 1000 and 500.
■ Installing & Commissioning of Huawei RTN 905,910,950,950A,980 and RTN320
■ Expertise on 1+0 link configuration 1+1 configuration XPIC configuration and SD configuration.
■ Link up gradation, dismantling and rectification.
■ Good expertise in using Huawei Tools as ISDP, WDT, MDT and Smart QC.
■ Installation, Commissioning, Integration, Troubleshooting & Expansion of
■ Transmission (Huawei RTN 320 & 900 series).
■ Hands-on Experience on RTN Integration Software Web LCT & BTS Integration Software.
■ Perform indoor & outdoor installation of Huawei sites.
■ Quality assurance at sites before PAT.
■ Fault location, isolation, troubleshooting and resolution, snag rectification.
■ Managed communications during major technology outages, natural disasters, virus outbreaks, frame cloud outages and network device outages.
■ Maintenance of 9kva, 13kva, 20kva, 27kva, 30kva generators of different vendors.
■ Sites Audit for PM [Preventive Maintenance] and CM [Corrective Maintenance] to check out the quality of Maintenance, give a better response to Customers, and manage Telco & Non-Telco teams.
■ Reporting of status for all sites with coordination of project control department.
■ Provides technical assistance to the staff and help in fault isolation and troubleshooting for troubled circuits