Career Objectives: Experienced Fire Fighting project Engineer accomplished in completing Fire Alarm Safety industrial projects quickly and cost effectively. Over 11 years of progressive Experience as a knowledgeable and talented Leader . Detail-oriented, organized and meticulous employee. Works at fast pace to meet tight deadlines. Enthusiastic team player ready to contribute to company success.
Overview
15
15
years of professional experience
1
1
Certification
Work History
Sr. Project Engineer
ETECHS
03.2014 - Current
11+ years of Experience in the field of Fire Alarm & Fire Fighting field
Testing all newly installed Fire Alarms
Communicated effectively with customers, answering questions concerns regarding systems.
Worked on Notifier Addressable FACPS Such as NFS2-3030,640E.320 as a programming and commissioning Engineer.
Worked on ONYX Workstation from Notifier Honeywell.
Visited sites to check Project progress and eliminate bottlenecks.
Scheduled projects and resources to meet deadlines whilst achieving target spending.
Reviewed designs, plans and reports to ensure constant compliance with project specifications.
Checked client requirements and generated solutions from identified needs.
Responded to maintenance calls and troubleshoot devices
Excellent grasp of NFPA & life safety codes
Finalizing all discipline deliverables for assigned projects.
Enforced health and safety protocols to minimize accidents and injury.
Coordination with all disciplines (as necessary) in the preparation and development of the deliverables and ensuring those other disciplines' inputs are incorporated for the assigned projects
Demonstrate features and functionality of fire alarm system to customers
Work According to NFPA Standards and Codes for each Specialization sector in fire systems
Collaborated with team and management to ensure a smooth workflow and efficient organization operations
Performed Preventive Maintenance on FACP Panels and extinguishing Systems savings customers 30% off future repair spending.
Optimized workplace procedures for safety, developing and updating process based on the latest search.
Surveyed sites to identify risks and adapt fire solutions accordingly.
Conducted post-fire inspections, analyzing incidents and implementing corrective measures.
Extensive design experience with water-based suppression systems, clean agent suppression systems, fire water pumps, fire water distribution systems, fire water storage tanks, foam suppression systems, hydrants, monitors, and fire extinguishers
Strong knowledge of fire detection alarm & suppression system and equipment
Monitored inventory and reported items to be restocked for each job.
Maintained documentation for areas such as orders, activities, schedules and employee performance.
Maintain records of Test & Inspection of All FDAS & FF systems for efficiency improvement on site and minimize risk and troubles related to fire detection and Suppression system.
Maintained Up to date knowledge of industry standards and emerging regulations related to fire safety.
Examined project plans and locations to identify and mitigate potential hazards.
Collaborated with engineering teams in creating testing and maintaining functional fire suppression systems.
Oversaw installation, testing and commissioning of engineering systems to meet performance and safety requirements.
Supported technicians in equipment maintenance and repair
Attended monthly safety meetings to ensure machine operation safety
Consistently assumed additional responsibilities and worked extended hours to meet project deadlines
Solving the technical queries of the customers.
Improved fire safety by conducting thorough inspections and identifying potential hazards in various building types.
Optimized existing fire protection systems by evaluating their performance, identifying deficiencies, and recommending improvements.
Conducted risk assessments and recommended appropriate fire protection measures for unique building designs or hazardous materials storage.
Performed hydraulic calculations for designing optimal water-based firefighting systems tailored to specific facility requirements.
Identified potential risks early in the process, allowing proactive mitigation measures to prevent delays or setbacks.
Reduced project completion times for increased client satisfaction by consistently meeting deadlines and delivering high-quality results.
Assisted in development of new standards and regulations to increase safety of future installations.
Conducted post-installation testing to establish system operations within prescribed metrics.
Prepared and presented technical reports on fire safety systems for both in-situ frameworks and proposed designs.
Reduced fire-related accidents by providing training sessions on fire prevention techniques and emergency response procedures.
Serviced fire extinguishers and building suppression systems on regular schedule to maintain occupant and structural safety.
Determined causes of fires and preventive efforts for future.
Project Engineer
Arab Builders for Telecommunication and Security Services, ABTSS
11.2012 - 08.2014
Testing and Inspection of Fire Extinguishers CO2, Powder Etc.
Conducted post fire inspections, analyzing incidents and implementing corrective measures.
Detected fire hazards and outlined details to mitigate the risk of fire.
Schedule tasks strategically to meet set deadlines for construction work.
Performed regular evaluations of all facility fire Systems
Installation of SIEMENS Addressable fire alarm system CEREBRUS PRO IP5 Version
Fire Fighting Services takes charge of checking Extinguishers on scheduled time and other service orders
Participate in meetings with external site teams and within own company environment
Consistently update my own technical knowledge
Collaborated with senior management and business line management to identify and prioritize new concepts for development and launch
Provided engineering support to the security team during commissioning phase of project
Monitored service capabilities and collaborated cross-functionally to ensure needs were met and escalated issues were resolved.
Reviewed designs, plans and reports to ensure constant compliance with project specifications.
Checked client requirements and generated solutions from identified needs.
Identified need for maintenance and repair work, scheduling as necessary.
Low Current system commissioning Engineer
PERFECT TELE SYSTEMS
07.2010 - 08.2012
Worked on almost all brands of CCTV including DVRS HIKVISION, DHUA, and HONEYWELL etc.
Communication with field operation manager and taking assistance whenever required
Installation and Commissioning of CCTV IP Cameras
Supervision of Cabling and Optical fiber laying and splicing with all hardware accessories
Documentation with client and internal organization required for project
Designing, troubleshooting, estimate installation, testing and commissioning of Fire Alarm System, CCTV and Access Control
Testing of all cables laid for Fire Alarm, CCTV and access Control like cable continuity check and other related tests before terminating them into their related panels
Commissioning and Configuration of all Fire Alarm System CCTV as per client requirements
Preparation of Fire Alarm CCTV and Access Control quotations based on selected quantities and submission of same for participating in bid
Following up with clients for payment towards amount of work completed at site
Work well in busy team, being quick to learn and able to deal with wide range of issues
Excellent understanding of business processes
ATTENDANCE SYSTEM USING RADIO FREQUENCY AND IDENTIFICATION (RFID, Functionality : Smart Card based Attendance System
CERBERUS PRO ADDRESSABLE FIRE ALARM SYSTEM IP5
Delivered on-site commissioning and acceptance testing of mechanical, electrical, control systems and automated processes.