A highly adaptable and innovative professional, skilled in analytical problem-solving and thriving in challenging environments. Demonstrates exceptional organizational abilities and dedication, consistently meeting deadlines under pressure. Excels both independently and collaboratively, with a strong work ethic and positive attitude.
FE-Mechanical (NCEES ID: 21-101-24)
https://account.ncees.org/rn/2110124-1724326-bdbbc17
· Reviewed the shop drawings for Firefighting and Plumbing systems and Method of statements, safety procedures, Technical RFI prior to submitting Client approval.
· Responsible for carry out the Installation Inspection for Firefighting system under the Supervision of P.E Firefighting Engineer and SAPID as per Aramco Standard Requirements.
· Witnessed the Installer Qualification of Various HDPE Installer at site and submitting their JCC to Aramco for Approval.
· Completely involved in kick of meetings, tool box meetings so that the quality requirements are fulfilled as per Standard Requirements.
· well aware of NFPA 13, NFPA, 14, NFPA 20, NFPA-10, IPC, UPC, UMC, IBC, SMACNA, NFPA 90A, ASHRAE and Saudi ARAMCO engineering standards and utilizing on day-to-day construction activities at the time of Installation and During Drawing Reviews, Technical Quarries.
· Carry out the installation of Underground DWV Drainage piping for building services, and RTR and Manholes for Infra sewer piping and NSF Approved RTR Piping for Potable water line and carry out the required testing and preparing the related documents and RFI for Client approval.
· Responsible for full coordination with other Construction department (such Electrical, Civil), procurement, Client on daily basis for better quality work and resolving any issues at site and coordinating with client for any dispute at site with respect other discipline work.
· Raised the INCR if any kind of violation of site activity occurs with respect to standard and project specification, or Manufacture recommendation.
· Created all the Inspection test plans for HVAC and Plumbing Discipline using SMACNA, UMC, IPC, NFPA 90A, UL 555 and Project specifications and IFC Drawings as reference documents.
· Designed Special Procedure for Brazing, applying standard reference such as ASME SEC ix and witnessed the Brazer qualification under third party approved company.
·Technically coordinated with the HVAC vendor and our procurement department while selection of HVAC Package units as per Standard and project specification requirements I.e. (AHRI, NEC, NFPA, IPC, ASHRAE and ARAMCO standards
· Witnessed Troubleshooting and start up of package units, Fan coil units, Fire Smoke Dampers, Exhaust Fans, smoke detectors, in the presence of Manufacture, client, Proponent and guiding the Construction team and Manufacturer for sequence of operation needed as per Design requirements.
· Reviewed and interpret detailed engineering drawing and specification related all Mechanical system (Duct Fabrication, Oily water system, Selection of Fire extinguisher) HVAC, Plumbing and Fire water system.
· Planned the two weeks look ahead, Minutes of Meeting for completion of work as per client schedule.
· Specified the selection of Non-metallic piping, Metallic piping, valves, fittings and their dimension requirements as per UPC standard tables ASME B31.3.
· Witnessed Troubleshooting and start up of package units, Fan coil units, Fire Smoke Dampers, Exhaust Fans, smoke detectors, in the presence of Manufacture, client, Proponent and guiding the Construction team and Manufacturer for sequence of operation needed as per Design requirements.
· Carrying out Hydrostatic test for Firefighting and plumbing system and preparing its related hydro packages prior to start of activity as per IPC and NFPA requirements.
· Carrying out Gravity test for Strom, sanitary and MANHOLES AND CATCH BASIN as per the IPC, UPC, standard requirement.
· Responsible for Verifying the installation of sprinkler, diffusers, grills, VAV, Fire damper, Fire smoke Damper, VD, Air curtain, Exhaust Fan, as per SMACNA, ASHARE, UL555, UL 555S, UMC, AMCA210 requirements.
· Carrying out Material receiving and Installation inspection of Manholes, plumbing fixtures, ROOF TOP UNITS, ENERGY RECOVERY UNIT, HDPE, RTR, UPVC, CPVC, PVC, GI PIPE, CATCH BASINS, PLUMBING COMPONENTS, FIRE FIGHTING COMPONENTS, HVAC components as per Standard requirements and cross verifying with project specification and IFC requirements.
· Responsible Witnessing the startup of Air Handling Units, Fans, Fire Jockey Pumps, Diesel Engine pumps, booster Pumps, RECIRCULATING PUMPS, Package UNITS, Fan coil Units, Chill water PUMPS, and Electric Water Heaters, as per Standard and Manufacture Requirements. (Standard Include, NFPA 20, SMACNA, ASHRAE, UL, IPC, Saudi Aramco, NFPA 70 etc.).
Prepared the pre commission packages for all HVAC equipment, plumbing system, and firefighting system by coordinating with electrical department.
· Reviewed and interpret detailed engineering drawing and specification related all Mechanical system (Duct Fabrication, Oily water system, Selection of Fire extinguisher) HVAC, Plumbing and Fire water system.